CCAC Leros
Contact
- Lepida, Leros, 85400
- ris.ccac.leros@migration.gov.gr
- 213 138 3000 (Director)
- 213 138 3001 (Deputy Director)
- Capacity and General Characteristics
Η Κλειστή Ελεγχόμενη Δομή στη Λέρο αναπτύσσεται σε έκταση περίπου 60 στρεμμάτων, στην τοποθεσία Λέπιδα.Είναι δυναμικότητας 2.150 θέσεων φιλοξενίας, η οποία αναλύεται ως ακολούθως:
- 1.440 θέσεις (γενικός πληθυσμός)
- 10 θέσεις ΑΜΕΑ
- 100 unaccompanied minors
- 240 persons belonging in vulnerable groups, single parent families, women
- 360 persons in the Pre-removal Detention Center
It contains all the modern technical and functional infrastructure that makes it a safe, controlled access facility, with upgraded living conditions for its residents and advanced working facilities for its staff.
Ο προϋπολογισμός κατασκευής είναι περίπου 30,18 εκ. ευρώ πλέον ΦΠΑ 17% (σύνολο 35,30 εκ. ευρώ) και χρηματοδοτήθηκε 100% από την Ευρωπαϊκή Ένωση – Ταμείο Ασύλου, Μετανάστευσης και Ένταξης/ Επείγουσα Βοήθεια.
- Safety
The whole new closed controlled center is surrounded by a double NATO-type security fence, which in combination with the installation at the entrance of the necessary control systems, such as turnstiles, magnetic gates, x-rays, two-factor access control system (identity and fingerprint), ensures secure and controlled entry and exit from the access center to whoever is entitled to it.
In addition, the installation of Closed Surveillance System (CCTV), uses "smart" software in order to warn in time for any emergency events, while it has the ability to give notifications and images to the Local Event Center, at the Control Center in Athens and at the Control Centers of other institutions (eg Hellenic Police).
Tourniquets with card readers have been placed in the separate sections of the new closed controlled access center for the protection of the employees and the vulnerable groups, such as unaccompanied children and single parent families.
- Structure and Accomodation Spaces
Οι χώροι διαμονής αναπτύσσονται σε 8.900 τ.μ. και διαιρούνται σε διακριτές ζώνες, ενώ αποτελούνται από 7 διώροφα κτίρια διαμονής των 1.000 τ.μ. με χωρητικότητα 240 άτομα ανά κτίριο, 3 ισόγεια κτίρια διαμονής των 500 τ.μ. με χωρητικότητα 120 άτομα ανά κτίριο και 1 των 400 τ.μ. με χωρητικότητα 100 άτομα. Η τοποθέτηση των αιτούντων άσυλο γίνεται βάσει εθνοτικών και κοινωνικών κριτηρίων (οικογένειες, άτομα με κινητικές αναπηρίες, σοβαρά προβλήματα υγείας, έγκυοι).
Στη ΚΕΔ Λέρου λειτουργούν οι κάτωθι χώροι:
- Accommodation spaces divided into separate zones (7 two-storey residential buildings sized 1.000 sq.m., and 1 ground floor of 400 sq.m., with a total capacity of 1.780 persons),
- Accommodation space of the Pre-removal Detention Center (3 ground floor accommodation buildings sized 500 sq.m. each, with a total capacity of 360 persons),
- Sanitary facilities (5 containers and 3 ground floor buildings with a total space of 850 sq.m.),
- Administration space (1 container and 6 ground floor buildings, with a total space of 1.045 sq.m.),
- Security areas (3 ground floor buildings, with a total space of 510 sq.m.),
- Maintenance and storage spaces (1 ground floor building and 2 containers, with a total space of 490 sq.m.),
- Leisure and creativity areas (11 containers, with a total space of 550 sq.m.),
- Computer room (1 container 50 sq.m.)
- Restaurants (6 ground floor buildings, with a total space of 2.650 sq.m.)
- Store areas (12 containers with a total space of 300 sq.m.),
- Kitchen and laundry areas (20 containers with a total space of 500 sq.m.),
- Event areas (2 ground floor buildings, total area 250 sq.m.)
- 2 playgrounds,
- 3 sports courts,
- Parking lot,
- 9 ισόγεια κτίρια ατόμων με κινητικά προβλήματα (ΑΜΕΑ) συνολικής επιφάνειας 175 τ.μ.
- 1 Shading sized 300 sq.m.
- 7 Shadings sized 150 sq.m.
The buildings are either metal constructions or prefabricated containers with complete hotel and office equipment.
An asphalt road has been constructed for the smooth movement around and between the units of the Closed Controlled Access Center.
- Technical Characteristics
All the necessary electromechanical systems for safe and uninterrupted operation of the new Closed Controlled Access Center have been installed, such as:
- Fire safety system with permanent water supply system, sprinklers, fire safety system
- Emergency power generators to ensure the power supply of the Closed Controlled Access Center
- Pumping complex for the connection to the network of the municipality of Leros
- Energy saving with Heat Recovery Hot Water System with VRV type heat pumps
- Air conditioning, heating-cooling with VRV type heat pumps & split type
- Wi-Fi Internet access indoors and outdoors
- Management and monitoring of operation of electromechanical equipment through BMS (Building Management System) automation system
- Use of LED luminaires for indoor and outdoor lighting
- Biological treatment of third-degree level wastewater
- Water saving by reusing the treated product of the biological treatment (gray water) in water tanks and irrigation
Για τη λειτουργία της Κλειστής Ελεγχόμενης Δομής Λέρου έχει προβλεφθεί η δημιουργία γραφειακής υποδομής για περίπου 300 θέσεις εργασίας.